Breathing is mechanics. The respiratory muscles create a pressure difference, the lung and chest wall stretch and recoil, and air flows through a branching set of tubes that resist it. Once these few forces make sense, pulmonary function tests stop being a list of numbers and start telling a story: a lung that won't empty, a lung that won't expand, or an airway narrowed at one fixed point.
Key points
- Functional residual capacity (FRC) is the resting point, where the lung's inward recoil and the chest wall's outward recoil balance; residual volume, FRC and total lung capacity can't be measured by spirometry.
- Obstruction lowers FEV1/FVC below about 0.7 and raises total lung capacity and residual volume; restriction lowers both FEV1 and FVC, keeps the ratio normal or high and lowers total lung capacity.
- Compliance rises in emphysema and with age, and falls in fibrosis, edema, ARDS and surfactant deficiency.
- Surface tension supplies much of the lung's recoil; surfactant lowers it, most of all in small alveoli, which keeps them open.
- Medium-sized bronchi contribute most airway resistance; flow-volume loops separate obstructive, restrictive, fixed and variable upper airway patterns.
Lung volumes and capacities
Four volumes, four capacities
The lung's contents are divided into four volumes that don't overlap, and capacities are sums of two or more of them[1].
| Volume | What it is | Typical adult value |
|---|---|---|
| Tidal volume (TV) | Air moved in a quiet breath | About 500 mL |
| Inspiratory reserve volume (IRV) | Extra air that can be breathed in after a quiet inspiration | About 3 L |
| Expiratory reserve volume (ERV) | Extra air that can be breathed out after a quiet expiration | About 1.2 L |
| Residual volume (RV) | Air left after a maximal expiration | About 1.2 L |
- Inspiratory capacity = TV + IRV.
- Functional residual capacity (FRC) = ERV + RV: the volume at the end of a quiet breath out, the resting point of the respiratory system.
- Vital capacity (VC) = TV + IRV + ERV: everything that can be moved.
- Total lung capacity (TLC) = VC + RV.
What spirometry can't measure
A spirometer measures only air that moves in and out. RV, FRC and TLC all include air that never leaves the lung, so they need helium dilution, nitrogen washout or body plethysmography[2]. The dilution methods only reach air spaces that communicate with the mouth; plethysmography also counts gas trapped behind closed airways, so in emphysema it reads higher than helium dilution.
Ventilation and dead space
Minute ventilation is TV × respiratory rate. Not all of it reaches alveoli: about 150 mL of each breath stays in the conducting airways, the anatomic dead space. Alveolar ventilation = (TV − dead space) × rate, so a patient who breathes shallowly and fast wastes a bigger share of every breath. A breath of 500 mL at 12 a minute gives 6 L of minute ventilation and (500 − 150) × 12 = 4.2 L of alveolar ventilation; 250 mL at 24 a minute gives the same 6 L but only (250 − 150) × 24 = 2.4 L to the alveoli.
Physiologic dead space adds alveoli that are ventilated but not perfused. The Bohr equation estimates it from the carbon dioxide gap: VD/VT = (PaCO₂ − PECO₂) ÷ PaCO₂, where PECO₂ is the carbon dioxide in mixed expired air. In health, physiologic and anatomic dead space are about the same[1].
Spirometry patterns
Forced spirometry records the FEV1 (air blown out in the first second) and the FVC (the whole forced breath)[3].
| Pattern | FEV1 | FVC | FEV1/FVC | TLC and RV |
|---|---|---|---|---|
| Obstructive (COPD, asthma, bronchiectasis) | Much lower | Lower or normal | Low (below about 0.7) | High: air trapping and hyperinflation |
| Restrictive (fibrosis, chest wall, neuromuscular) | Lower | Lower | Normal or high | Low |
A low FVC alone doesn't prove restriction, because air trapping in obstruction also lowers it. Restriction is confirmed by a low TLC[2]. Current standards also judge a result as abnormal against the lower limit of normal for the person's age, sex and height, rather than a single fixed cutoff[2]. COPD guidelines still diagnose the disease with a simple fixed rule: a post-bronchodilator FEV1/FVC below 0.7 in someone with symptoms and exposure[4].
Compliance, elastic recoil and surface tension
Compliance
Compliance is the change in volume for a given change in pressure: C = ΔV ÷ ΔP. A compliant lung is easy to inflate. Elastance, its reciprocal, describes how strongly the lung springs back.
- Higher lung compliance: emphysema, where elastic fibers are destroyed, and aging.
- Lower lung compliance: pulmonary fibrosis, pulmonary edema, surfactant deficiency in neonatal respiratory distress syndrome, and ARDS.
Two recoils and a resting point
The lung recoils inward, from its elastic fibers and from surface tension. The chest wall recoils outward. A thin film of pleural fluid couples them, which produces a negative intrapleural pressure of about −5 cm H₂O at FRC. At FRC the two recoils are equal and opposite, so the system rests there without any muscle work[1].
- Pneumothorax: air enters the pleural space, intrapleural pressure rises to atmospheric and the coupling is lost. The lung collapses inward and the chest wall springs outward.
- Emphysema: less inward recoil, so the balance point moves up. FRC rises and the chest becomes barrel-shaped.
- Fibrosis: more inward recoil, so FRC falls.
Pressures during a breath
When the diaphragm contracts, intrapleural pressure becomes more negative, alveolar pressure falls below atmospheric and air flows in. At the end of inspiration and expiration there is no flow, so alveolar pressure equals atmospheric pressure. During a forced expiration intrapleural pressure becomes positive and squeezes the airways. Beyond a certain effort, flow can't rise any further (it becomes effort-independent), and airways with weak walls, as in emphysema, collapse early and trap air[1].
Surface tension and surfactant
At least half of the lung's recoil comes from surface tension at the air-liquid interface lining the alveoli. A lung filled with saline has no such interface and is far more compliant than an air-filled one.
The law of Laplace, P = 2T ÷ r, explains why this matters. For the same surface tension (T), a small alveolus needs more pressure to stay open than a large one, so without help small alveoli would empty into large ones and collapse.
Surfactant, mainly dipalmitoylphosphatidylcholine made by type II pneumocytes, lowers surface tension, and lowers it most in small alveoli, where the surfactant film is packed tightest as the alveolus shrinks[1]. As a result surfactant:
- keeps alveoli of different sizes stable,
- raises compliance and lowers the work of breathing,
- helps keep fluid out of the alveoli.
Hysteresis is the difference between the inflation and deflation curves of an air-filled lung: at any given pressure, the lung holds more volume on the way down than on the way up. It comes mainly from how surfactant behaves at the interface, so a saline-filled lung shows little hysteresis.
Hyperinflation in emphysema
In severe emphysema, TLC and especially RV climb well above predicted. With less elastic recoil, the lung no longer pulls the chest wall in, and airways collapse during exhalation and trap air. FRC and RV rise, the diaphragm is flattened, and each contraction moves less air.
Airway resistance and flow-volume loops
Where resistance comes from
Poiseuille's law, R = 8ηl ÷ πr⁴, puts the radius at the fourth power: halve the radius of an airway and its resistance rises 16-fold[1]. Yet each small airway, although narrow, is one of thousands arranged in parallel, so together they offer little resistance. Most of the total resistance comes from the medium-sized bronchi. That is why disease of the small airways can progress silently before routine tests change.
| Raises resistance | Lowers resistance |
|---|---|
| Bronchial smooth muscle contraction: parasympathetic M3 signaling, histamine, leukotrienes | Beta-2 agonists |
| Mucus and airway wall edema | High lung volume: the surrounding lung tissue pulls airways open |
| Low lung volume, with less radial traction | Low-density gas such as heliox |
| Dense gas, as in deep diving |
Reading a flow-volume loop
A flow-volume loop plots forced expiration above the axis and forced inspiration below it[3]. Its shape points to where the problem is.
| Pattern | Loop shape | Examples |
|---|---|---|
| Obstructive | Scooped, concave expiratory limb; loop shifted to higher volumes | COPD, asthma |
| Restrictive | Normal shape but narrow, shifted to lower volumes; flow can be high for the volume | Fibrosis, chest wall disease |
| Fixed upper airway obstruction | Both limbs flattened into a box | Tracheal stenosis after intubation or tracheostomy; a goiter compressing the trachea |
| Variable extrathoracic obstruction | Inspiratory limb flattened | Vocal cord paralysis, laryngeal tumor |
| Variable intrathoracic obstruction | Expiratory limb flattened | Tumor of the lower trachea or a main bronchus, tracheomalacia |
The variable patterns follow the pressures around the airway. An extrathoracic airway narrows during inspiration, when the pressure inside it falls below atmospheric. An intrathoracic airway narrows during expiration, when the pressure in the chest rises around it. A fixed lesion, such as a goiter squeezing the trachea to a set width, limits flow equally in both directions.
Common confusions
- Compliance versus elastance: they are reciprocals. Emphysema has high compliance and low recoil; fibrosis has low compliance and high recoil.
- Low FVC versus restriction: obstruction with air trapping also lowers FVC. Only a low TLC proves restriction.
- Stridor versus wheeze: stridor is a harsh noise from the large airways, often on inspiration; wheeze is musical, comes from narrowed smaller airways and is mostly expiratory. Stridor on both inspiration and expiration suggests a fixed obstruction.
- Plethysmography versus helium dilution: only plethysmography counts gas trapped behind closed airways, so the two differ most in emphysema.
References
- Hall JE, Hall ME. Guyton and Hall Textbook of Medical Physiology. 14th ed. Elsevier; 2021. ↩
- Stanojevic S, Kaminsky DA, Miller MR, et al. ERS/ATS technical standard on interpretive strategies for routine lung function tests. Eur Respir J. 2022;60(1):2101499. doi:10.1183/13993003.01499-2021 Link ↩
- Graham BL, Steenbruggen I, Miller MR, et al. Standardization of spirometry 2019 update: an official American Thoracic Society and European Respiratory Society technical statement. Am J Respir Crit Care Med. 2019;200(8):e70-e88. doi:10.1164/rccm.201908-1590ST Link ↩
- Agustí A, Celli BR, Criner GJ, et al. Global Initiative for Chronic Obstructive Lung Disease 2023 report: GOLD executive summary. Eur Respir J. 2023;61(4):2300239. doi:10.1183/13993003.00239-2023 Link ↩