med study partner

Articles & Guides › Articles › Cardiovascular

Cardiac action potentials and the ECG

Which ion carries each phase of the muscle and pacemaker action potentials, how the autonomic nervous system and drugs change the heart rate, how fast each part of the conduction system conducts, and how to read the waves, intervals, axis and electrolyte changes on an ECG.

Cardiovascular · 6 min read · Reviewed 2026-11-09

Most of cardiac pharmacology and most arrhythmias make sense once you know which ion carries which phase of the action potential. Sodium makes the fast upstroke in heart muscle, calcium makes the plateau, potassium brings the cell back down, and a slow "funny" sodium current sets the pace in the SA node. The conduction system spreads that signal at very different speeds, and the ECG records the result from the skin. This article covers the two kinds of cardiac action potential, autonomic control of heart rate, the conduction system, and how to read an ECG.

Key points

  • In heart muscle, phase 0 is sodium entering, the plateau is calcium entering balanced by potassium leaving, and repolarization is potassium leaving.
  • In the SA and AV nodes, phase 0 is calcium, and the slope of phase 4, set by the funny current, sets the heart rate.
  • Sympathetic stimulation steepens phase 4; the vagus flattens it and hyperpolarizes the cell.
  • Conduction is fastest in the Purkinje fibers and slowest in the AV node, whose delay is most of the PR interval.
  • High potassium peaks the T waves and then widens the QRS; give IV calcium first to stabilize the heart.

The ventricular myocyte action potential

Atrial and ventricular muscle and Purkinje fibers have a stable resting potential and a fast action potential with five phases[1,2].

PhaseNameMain current
4Resting potential (about −90 mV)Potassium leaking out keeps the cell near the potassium equilibrium potential
0Rapid upstrokeFast sodium channels open; sodium rushes in
1Early repolarizationSodium channels inactivate; a brief potassium outflow
2PlateauCalcium enters through L-type channels, balanced by potassium leaving
3Rapid repolarizationCalcium channels close; delayed rectifier potassium channels carry potassium out

Excitation–contraction coupling

The calcium that enters during the plateau triggers the sarcoplasmic reticulum to release a much larger store (calcium-induced calcium release). Calcium binds troponin C, letting actin and myosin interact. To relax, calcium is pumped back into the sarcoplasmic reticulum by SERCA and out of the cell by the sodium-calcium exchanger[1]. Digoxin blocks the sodium-potassium pump, so sodium builds up inside the cell, less calcium is exchanged out, and contractility rises[3].

Because of the long plateau, the heart's refractory period lasts almost as long as its contraction, so heart muscle cannot be tetanized. A stimulus that falls in the vulnerable late part of repolarization, such as a premature beat on the T wave, can trigger ventricular fibrillation.

Potassium and calcium

The resting potential depends mainly on the potassium gradient. High potassium makes the resting potential less negative. Sustained depolarization inactivates sodium channels, so the upstroke slows, conduction slows and the QRS widens, leading to bradycardia, sine waves and cardiac arrest[1]. Calcium raises the threshold potential, restoring the gap between resting and threshold potentials. That is why IV calcium is given first when high potassium changes the ECG: it protects the heart within minutes, while insulin with glucose and other treatments lower the potassium itself.

Pacemaker action potentials and autonomic control

The SA and AV nodes have a slow action potential with no stable resting potential and no plateau[2].

PhaseMain current
4 (slow depolarization)The funny current (If): sodium entering through HCN channels that open when the cell is most negative; later, T-type calcium channels
0 (upstroke)L-type calcium channels; a slower upstroke, which is why nodal conduction is slow
3 (repolarization)Potassium leaving

The slope of phase 4 sets the heart rate. The SA node has the steepest slope, so it overrides slower pacemakers: the SA node fires at 60–100 per minute, the AV junction at 40–60 and the ventricles at 20–40[1].

InputEffect on the node
Sympathetic (norepinephrine on beta-1 receptors)Steeper phase 4 (faster rate), faster AV conduction, stronger and faster contraction
Parasympathetic (acetylcholine on M2 receptors)Flatter phase 4, and potassium channels open to hyperpolarize the cell; slower AV conduction
Adenosine (A1 receptors)Like the vagus; briefly blocks the AV node

Drugs act at the same points[3]. Ivabradine blocks the funny current, slowing the SA node without lowering contractility or blood pressure. It is used in heart failure when the heart rate stays high despite a beta-blocker[4]. Beta-blockers and verapamil or diltiazem slow phase 4 and AV conduction. Atropine blocks M2 receptors and speeds both.

The conduction system and conduction velocity

The impulse starts in the SA node, at the junction of the superior vena cava and the right atrium, spreads across the atria, reaches the AV node near the opening of the coronary sinus, and passes down the bundle of His, the right and left bundle branches and the Purkinje fibers into the ventricles[1].

From fastest to slowest, conduction runs: Purkinje fibers, then atria, then ventricular muscle, then the AV node.

  • Purkinje fibers are large and well connected, so they activate both ventricles almost at once.
  • The AV node is slowest, because its upstroke depends on calcium and it has few gap junctions. Its delay lets the atria finish emptying before the ventricles contract, protects the ventricles from very fast atrial rhythms, and makes up most of the PR interval[5].

Heart rate, conduction speed and contractility are separate properties: a drug can lengthen the PR interval without changing the heart rate.

Reading the ECG: waves, intervals and axis

Wave or intervalRepresentsNormal value
P waveAtrial depolarizationUnder 120 ms
PR intervalAtria to ventricles, mostly AV nodal delay120–200 ms
QRS complexVentricular depolarizationUnder 120 ms
ST segmentThe plateau, when the ventricles are fully depolarizedFlat
T waveVentricular repolarizationUpright in most leads
QT intervalThe whole ventricular action potentialCorrected QT under about 440 ms in men and 460 ms in women

At the standard paper speed, each small box is 40 ms and each large box 200 ms. The heart rate is about 300 divided by the number of large boxes between beats[1].

Leads: II, III and aVF look at the inferior wall; I and aVL at the high lateral wall; V1–V2 at the septum; V3–V4 at the front wall; V5–V6 at the lateral wall.

Axis

The normal QRS axis is about −30° to +90°. If the QRS is positive in both lead I and aVF, the axis is normal. If lead I is positive and aVF negative, check lead II: positive is still normal, and negative is left axis deviation, as in left anterior fascicular block. If lead I is negative and aVF positive, there is right axis deviation, as in right ventricular hypertrophy[5].

Bundle branch blocks

A blocked bundle branch widens the QRS to 120 ms or more, because one ventricle is activated slowly through muscle. Right bundle branch block gives an "rSR′" pattern in V1; left bundle branch block gives a broad, notched R wave in V6 and a deep S wave in V1[5].

Electrolytes

DisturbanceECG change
High potassiumPeaked T waves, then flat P waves, a wide QRS and a sine-wave pattern
Low potassiumFlat T waves, U waves, ST depression
High calciumShort QT
Low calciumLong QT
Low magnesiumLong QT and risk of torsades de pointes[6]

Common confusions

  • Phase 0 in muscle versus node: sodium in muscle (class I drugs act here), calcium in the nodes (class IV drugs act here).
  • Why calcium is given in high potassium: it stabilizes the membrane but does not lower potassium.
  • Ivabradine versus beta-blockers: ivabradine slows the heart rate without reducing contractility or blood pressure.
  • The slowest conducting tissue is the AV node, not ventricular muscle.

References

  1. Hall JE, Hall ME. Guyton and Hall Textbook of Medical Physiology. 14th ed. Elsevier; 2021. ↩
  2. Grant AO. Cardiac ion channels. Circ Arrhythm Electrophysiol. 2009;2(2):185-194. doi:10.1161/CIRCEP.108.789081 Link ↩
  3. Vanderah TW, ed. Katzung's Basic and Clinical Pharmacology. 16th ed. McGraw Hill; 2024. ↩
  4. Heidenreich PA, Bozkurt B, Aguilar D, et al. 2022 AHA/ACC/HFSA guideline for the management of heart failure: a report of the American College of Cardiology/American Heart Association Joint Committee on Clinical Practice Guidelines. Circulation. 2022;145(18):e895-e1032. doi:10.1161/CIR.0000000000001063 Link ↩
  5. Kusumoto FM, Schoenfeld MH, Barrett C, et al. 2018 ACC/AHA/HRS guideline on the evaluation and management of patients with bradycardia and cardiac conduction delay: a report of the American College of Cardiology/American Heart Association Task Force on Clinical Practice Guidelines and the Heart Rhythm Society. Circulation. 2019;140(8):e382-e482. doi:10.1161/CIR.0000000000000628 Link ↩
  6. Schwartz PJ, Ackerman MJ. The long QT syndrome: a transatlantic clinical approach to diagnosis and therapy. Eur Heart J. 2013;34(40):3109-3116. doi:10.1093/eurheartj/eht089 Link ↩

Test yourself in the Question Bank · Listen to the podcasts